MVHR repair · Call-outs · London
MVHR Repair in London
Noisy fans, a unit that has stopped, condensation coming back or a warning light that will not clear. Our ventilation engineers find the fault, give you a written price and repair it, with a photographed report at the end of every visit.
- 24/7 line
- Back to you within 4 hours
- NICEIC DV-02 ventilation

- 1,000+properties served across London
- 4-hour responsewe come back to you within 4 hours
- Guaranteedworkmanship on every job
- £5M insuredpublic liability, SafeContractor approved
Who Repairs MVHR Units in London?
Mainteniq repairs mechanical ventilation with heat recovery (MVHR) units in flats, houses and blocks across London. Our engineers are NICEIC Domestic Ventilation (DV-02) certified and work on most makes found in London new builds.
This page is for a unit that has gone wrong. For planned filter changes and yearly servicing, see MVHR servicing and maintenance.
Short answer
- We come back to you within 4 hours, with same-day attendance across London.
- A written price before any repair.
- A photographed report through Maintivo after every visit.
Symptom, cause, repair
Common MVHR Faults and What Causes Them
Find the symptom that matches yours. Each card shows the usual causes and what our engineer does about it.
Unit not running
Usual causes: No power at the fused spur, a tripped breaker, a failed fan motor, a control board fault or a controller that has lost its settings.
What we do: We check the supply first, then test each fan and the board to find the part that has failed.
Loud or rattling fan
Usual causes: Dust on the fan impellers, a worn bearing, blocked filters making the fans work harder, or a loose duct or grille rattling in the ceiling.
What we do: We open the unit, clean or balance the fans, tighten the ducts we can reach and replace a worn fan.
Condensation and mould
Usual causes: The unit is no longer extracting enough moist air from the kitchen and bathrooms: blocked filters, a slow fan, a crushed duct or grilles turned shut.
What we do: We measure the airflow at the grilles, find where it is lost and set the system back to its design rates.
Blocked or dirty filters
Usual causes: Filters left too long load up with city dust and pollen. Airflow drops, the fans strain and the rooms start to feel stuffy.
What we do: We fit the right filters for your make and model and check the heat exchanger behind them.
Filter warning light stays on
Usual causes: Most controllers count down to the next filter change and need a reset after it. A warning that comes straight back can point to a sensor or setting.
What we do: We change the filters, reset the reminder the way the maker sets out and check it clears.
Boost not working
Usual causes: A faulty boost switch, pull cord, humidity sensor, wiring fault or a controller setting. Bathrooms stay steamed up after a shower.
What we do: We test the switch, the sensor and the wiring back to the unit, then confirm boost lifts the fan speed.
Bad smells
Usual causes: Dirty filters, a dry or blocked condensate trap letting drain smells back up, or the supply and extract mixed up at the grilles.
What we do: We clean or replace the filters, refill and clear the trap and check each grille is doing the right job.
Damp or water dripping
Usual causes: MVHR units make condensate in cold weather. A blocked trap, a split drain or a badly insulated duct can drip into the ceiling or cupboard below.
What we do: We clear the drain, check its fall and look at the duct insulation near the unit.
Frost protection faults
Usual causes: In freezing weather many units slow the supply fan or switch on a preheater to stop the heat exchanger icing. If that fails the unit can stop, run unbalanced or drip as it thaws.
What we do: We test the frost protection, the preheater where one is fitted and the temperature sensors.
Failed motor or circuit board
Usual causes: Fans and control boards wear out over the years, and a power surge can damage a board. The unit stops, or one fan runs while the other does not.
What we do: We confirm which part has failed, source the right replacement and fit it once you have approved the written price.
Controller faults
Usual causes: A blank display, an error code, buttons that do nothing or a wireless controller that has lost its link to the unit.
What we do: We read the error, check the cable or link to the unit and reset or replace the controller.
Before you call
Five Quick Checks
These take a minute and help the engineer arrive with the right parts. Leave the covers on: the inside of the unit is a job for us.
- Is the switch or fused spur next to the unit on?
- Has a breaker tripped in the consumer unit?
- Is there an error code or warning on the controller? Take a photo of it.
- Is water dripping from the unit or the ceiling? Put a bowl under it and call us.
- Take a photo of the label on the unit, so we know the make and model.


How an MVHR Repair Visit Works
Five steps, from your first call to the report in your inbox.
- 1
Tell us what is happening
Call or WhatsApp us with the symptoms and a photo of the unit label. We come back to you within 4 hours and offer same-day attendance across London.
- 2
Diagnosis on site
The engineer tests the power, fans, filters, condensate drain, sensors and controller, and measures airflow at the grilles where it is needed.
- 3
Written price first
You get a written price before any repair starts. Nothing is replaced until you have said yes.
- 4
The repair
The fault is repaired. If a part has to be ordered, the unit is made safe and we book the return visit with you.
- 5
Photographed report
Every visit ends with a photographed report sent through Maintivo: what we found, what we did and the readings taken.
Water Coming Through the Ceiling?
Switch the unit off at its spur, catch the water and call our 24/7 line. A dripping MVHR is usually a blocked condensate drain. For other urgent heating, cooling and ventilation faults, see emergency HVAC repair.
A photographed PDF report after every MVHR repair
No handwritten job sheets and no chasing. Our engineers complete each job electronically on site in Maintivo, our job management system, so the report is built as the work happens: photos, readings, work done and recommendations.
You receive it as a digital PDF by email the same day, with certificates attached where they apply, ready to forward to a landlord, a freeholder, the directors or an insurer.
- Before and after photosEvery unit and fault photographed on site
- Readings and checksTemperatures, pressures and test results recorded
- Work done and next stepsWhat was fixed, what needs quoting, when we return
- Sent the same dayDigital PDF report by email, ready to forward
Example layout. Completed on site in Maintivo.
Why Book Mainteniq for an MVHR Repair
What customers say on Google
“I've had the pleasure of working with Petru and his team on a number of maintenance jobs, and they've always been fantastic. They're professional, reliable, and complete every job to a really high standard. Petru is incredibly knowledgeable and it's clear he takes pride in his work.”
Deborah L.
Google review
“Excellent service. Price assessment: reasonable price.”
Attila B.
Google review
“The team is knowledgeable, efficient, and attentive to detail. A great choice for anyone looking for reliable maintenance services. Highly recommended!”
Ben
Google review
Book an MVHR Repair