Evinox Energy · ModuSat · London

Evinox HIU Service and Repair in London

Servicing and repairs for Evinox ModuSat heat interface units in London flats, build-to-rent blocks and heat networks, by Evinox trained and certified engineers, with a 24/7 HIU call-out line.

Call +44 783 456 2366
  • Evinox trained and certified engineers
  • Free site visit in London
  • 24/7 HIU call-out
Engineer testing the electronics of a wall-mounted heat interface unit in a London flat cupboard, Mainteniq London

Who services Evinox HIUs in London?

Mainteniq services and repairs Evinox ModuSat heat interface units across London and the Home Counties. Our engineers are trained and certified by Evinox Energy to work on Evinox heat interface units: our director, Petru Diaconu, completed Evinox's HIU Training Programme on 5 March 2024. Our engineers are also manufacturer approved for SAV and Danfoss units and hold the SAV Advanced HIU Service Engineer certificate. Every visit ends with a report with photos and the readings taken, and our emergency line runs 24/7 for no heating or no hot water.

Mainteniq is an independent contractor and is not part of Evinox. Evinox Energy designs and develops its ModuSat units in the UK, and its published projects include London schemes such as Battersea Power Station, London City Island and Wood Wharf. If the label in your cupboard says Evinox or ModuSat, this is the right page. For other makes, see Danfoss, SAV or our HIU service and repair page.

How an Evinox ModuSat HIU Works

A heat interface unit connects one flat to the building's shared heating. It takes heat from the network and turns it into the flat's own hot water and heating, so the flat needs no boiler. This is how Evinox describes its ModuSat XR Twin Plate.

  1. STEP 1

    Heat from the network

    Hot water arrives from the block's plant room or a district heat network. Evinox rates the ModuSat XR for primary water up to 85°C.

  2. STEP 2

    Valves and heat meter

    Two electronic pressure independent control valves let in just enough network water, and an ultrasonic heat meter records what the flat uses.

  3. STEP 3

    Two plate heat exchangers

    On a Twin Plate unit, one stainless steel plate heats the radiators or underfloor heating and the other heats the tap water. The waters never mix.

  4. STEP 4

    Hot water comes first

    A flow sensor on the cold inlet starts hot water the moment a tap opens. Hot water takes priority and pauses the heating until the tap closes.

  5. STEP 5

    Cooled water goes back

    The cooled water returns to the network. Evinox designs ModuSat units for a low return temperature, the sign of a healthy unit.

Because the network water and the flat's water never mix, most faults sit inside the HIU itself: the strainers, the plate heat exchangers, the control valves or the pump. All of them can be serviced.

Know your unit

Which Evinox ModuSat Do You Have?

These are the ModuSat models Evinox lists in its datasheets and manuals. The model is on the label behind the front panel and in the building's O&M file.

ModuSat XR Twin Plate

Heating plus instant hot water, through two separate plate heat exchangers.

ModuSat XR-ECO Twin Plate

A Twin Plate unit Evinox designed for heat networks running as low as 60°C, or even 55°C.

ModuSat XR SP-DH

Direct heating with instant hot water: network water runs through the flat's radiators.

ModuSat XR SP-DHW

Instant hot water only, with no heating circuit.

ModuSat SP-H and SP-C

Single plate units for heating only or cooling only.

ModuSat SPDC

Heating plus a separate hot water tank fed by the unit.

ModuSat XR CHHC

Heating, instant hot water and cooling in one case.

ModuSat FS

A floor standing unit with its own hot water tank built in.

Send a photo of your HIU label

Controls you may see with a ModuSat

Evinox units often come with its own controls and metering. Your block may use some, all or none of them.

ViewSmart
The room controller on the wall that programmes the heating. It is powered by the HIU, so it needs no batteries.
SmartTalk
Evinox's two-way communication system for remote metering, alarms and diagnostics, linked through a data logger in the building.
PaySmart
Evinox's prepayment upgrade for the ViewSmart controller, switched on remotely with no extra hardware.
Heat meter
Ultrasonic and MID approved, built into the unit. It can also read cold water, chilled water and electricity meters.
Inside a heat interface unit in a London flat cupboard, showing insulated valves, the expansion vessel and the heat meter, Mainteniq London
Inside a flat's heat interface unit: valves, expansion vessel and heat meter.

Common Evinox ModuSat Problems and What Causes Them

Evinox's ModuSat manuals explain what the pump light means, which behaviour is normal and what damages the unit. These are the faults we see most, with what Evinox says about each.

Red light on the pump

Evinox's manual: red and green blinking means the pump stopped for a voltage or overheating problem and restarts once it clears. Red blinking means it is blocked and must be replaced.

Heating slow to start

Often normal. When a ModuSat XR switches to heating, the pump runs for about two minutes before the heating valve opens, and running a hot tap pauses the heating.

Heating pressure too low

Evinox gives the flat's heating circuit an operating pressure of 1 to 2.5 bar, filled to about 1 bar. Pressure that keeps dropping needs checking for a leak.

Lukewarm hot water

High hot water temperatures scale the hot water plate heat exchanger. Evinox recommends a maximum of 55°C, especially in hard water areas, and most of London is one.

Blocked strainers

Evinox requires strainers on the network and heating inlets to keep debris out of the unit. When they clog, flow drops and hot water or heating fades.

Leak inside the casing

Evinox's advice: take care, as the water is hot, and slowly close the isolation valves at the top or bottom of the unit. Then call us to trace and repair it.

Clogged heat interface unit strainer next to a clean one during a Mainteniq London HIU service
A clogged strainer next to a clean one: one of the first things we check when hot water or heating fades.

Evinox's pump light guide in short: solid green is running, a fast green blink is standby, red and green is a temporary stop, red is a blocked pump and no light means no power.

Cold patches on underfloor heating rather than radiators? The fault may be at the manifold: see underfloor heating repair. If several flats lose heat at once, the cause is usually the plant room or the network, not the HIUs: call our 24/7 emergency line and see heat network maintenance.

What we do

Evinox ModuSat HIU Services

Evinox says its units must be maintained by qualified, competent people. Ours are Evinox trained and certified, and they work from a single flat with no hot water to every ModuSat in a block.

Evinox asks for 700 mm of clear space in front of the unit for servicing, so it helps to clear the cupboard before we arrive.

Engineer at a flat door with the block manager during a whole-block heat interface unit servicing programme, Mainteniq London
Whole-block servicing: access arranged with the building team, flat by flat.

Evinox HIU service

Worked through Evinox's own inspection checklist: leaks, isolation valves, strainers, network pressure, insulation, heating pressure, valves, pump, heat meter and a water sample, with a report with photos.

HIU servicing

Evinox HIU repair

No hot water, no heating, lost pressure, noise and leaks, traced to the part and repaired. We always aim to fix it on the first visit.

Pumps, valves and actuators

The heating pump, both pressure independent control valves and their actuators, the flow sensor and temperature sensors tested and exchanged.

Plate heat exchangers and water

Scaled plates cleaned or replaced, and the flat's heating circuit checked for inhibitor, which Evinox says must be topped up after radiators are removed for decorating.

ViewSmart and metering checks

The ViewSmart room controller tested for calling heat, the heat meter checked for registering use, and remote reading confirmed where the block uses it.

Whole-block programmes

Every ModuSat in a block on one programme, with access arranged, a report per flat and a block summary.

Block contracts

24 months

the longest gap Evinox recommends between checks

How Often Should an Evinox HIU Be Serviced?

Evinox's ModuSat manuals recommend the unit is checked at least every 24 months by an authorised maintenance engineer, and more often where it is heavily used or in a light commercial setting, in line with BSRIA's heat interface unit guide. In London blocks we recommend an annual service: hard water scales the hot water plate heat exchanger faster, and a yearly visit catches slow hot water before it becomes no hot water. We record the ModuSat model and serial details on every report.

Read more: how often should an HIU be serviced?

24/7 HIU Call-Out for No Heating or No Hot Water

Our emergency line is answered day and night, weekends included. For no heating or no hot water we aim to attend the same day across London. We always aim to fix the fault on the first visit; if a part has to be ordered, the flat is made safe and you get a fixed price first.

Call 24/7

How an Evinox HIU Job Works

  1. 1

    Free site visit

    We look at the ModuSat, the pressure gauge, the pump light, the riser and the controls. Free in London; in the Home Counties, free for larger jobs, otherwise we quote the visit first.

  2. 2

    Report with photos

    Which ModuSat model you have, what is working, what is worn and what needs doing, sent by email.

  3. 3

    Clear price

    A fixed price for the repair or service before any work, priced per unit for blocks, with guarantee terms set out in your quote.

  4. 4

    Planned visits

    Annual servicing on an agreed schedule, with a new report every visit.

Digital reports, not paperwork

A photographed PDF report after every Evinox HIU service

No handwritten job sheets and no chasing. Our engineers complete each job electronically on site in Maintivo, our job management system, so the report is built as the work happens: photos, readings, work done and recommendations.

You receive it as a digital PDF by email the same day, with certificates attached where they apply, ready to forward to a landlord, a freeholder, the directors or an insurer.

  • Before and after photosEvery unit and fault photographed on site
  • Readings and checksTemperatures, pressures and test results recorded
  • Work done and next stepsWhat was fixed, what needs quoting, when we return
  • Sent the same dayDigital PDF report by email, ready to forward

Example layout. Completed on site in Maintivo.

Qualifications Behind the Work

Evinox trained and certified engineersTrained and certified by Evinox Energy to work on Evinox heat interface units, through Evinox's HIU Training Programme, completed on 5 March 2024. Mainteniq is an independent contractor, not part of Evinox.
Manufacturer approvedFor SAV and Danfoss units; Evinox trained and certified
SAV Advanced HIU Service EngineerCertificate PERS-30839
REFCOM F-Gas certifiedREF1024168
NICEIC Domestic VentilationDV-02 certified
Gas SafeGas work by Gas Safe registered engineers

What customers say on Google

5.0Google rating
“I've had the pleasure of working with Petru and his team on a number of maintenance jobs, and they've always been fantastic. They're professional, reliable, and complete every job to a really high standard. Petru is incredibly knowledgeable and it's clear he takes pride in his work.”

Deborah L.

Google review

“Excellent service. Price assessment: reasonable price.”

Attila B.

Google review

“The team is knowledgeable, efficient, and attentive to detail. A great choice for anyone looking for reliable maintenance services. Highly recommended!”

Ben

Google review

Read all reviews on Google

Book a Free Evinox HIU Site Visit

In London an Evinox trained and certified engineer comes to see your ModuSat for free; in the Home Counties it is free for larger jobs, and for smaller ones we quote the visit first. You get a report with photos and a fixed price before any work.

WhatsApp us Call

Evinox HIU: Common Questions

Yes. Mainteniq's engineers are Evinox trained and certified to work on Evinox heat interface units, including the ModuSat range. Mainteniq's director, Petru Diaconu, completed Evinox's HIU Training Programme on 5 March 2024. Our engineers are also manufacturer approved for SAV and Danfoss units and hold the SAV Advanced HIU Service Engineer certificate (PERS-30839).

Yes. Mainteniq services and repairs Evinox ModuSat heat interface units across London and the Home Counties, including ModuSat XR and XR-ECO Twin Plate units, single plate heating, hot water and direct heating units, combined heating and cooling units and floor standing units with a hot water tank. Every visit ends with a report with photos, and our 24/7 line covers no heating or no hot water.

No. Mainteniq is an independent heating and building services contractor and is not part of Evinox Energy. Our engineers are trained and certified by Evinox Energy to work on Evinox heat interface units, and we also service SAV, Danfoss and most other makes found in London communal heating schemes.

ModuSat is Evinox Energy's range of heat interface units, the box in a flat's cupboard that takes heat from the building's communal or district heating and turns it into the flat's hot water and heating. The ModuSat XR Twin Plate, for example, has one plate heat exchanger for heating and another for instant hot water.

Evinox's ModuSat installation manuals recommend the unit is checked at least every 24 months by an authorised maintenance engineer, and more often where it is heavily used. In London blocks we recommend an annual service, because hard water scales the hot water plate heat exchanger faster.

That is normal. Evinox's manual explains that when a ModuSat XR switches to heating, the pump runs for about two minutes before the heating valve opens while the unit checks the heating circuit temperature. If the heating still does not warm up after that, an engineer should check the valves, pump and controls.

Evinox's ModuSat XR datasheet gives an operating pressure for the flat's heating circuit of 1 to 2.5 bar, and the manual says to cold fill it to about 1 bar. If the gauge on the front of the unit reads below that, or the heating keeps losing pressure, the circuit needs topping up and checking for a leak.

Evinox's manual lists the pump light states. Solid green means the pump is running normally and a fast green blink means it is on standby. Red and green blinking means the pump has stopped for a voltage or overheating problem and will restart itself once it clears. Red blinking means the pump is blocked and needs replacing, and no light means it has no power.

We check that the ViewSmart room controller calls for heat and that the unit can be read remotely where the block uses it, and we report any communications fault we find. Evinox's SmartTalk system, prepayment upgrades and billing services are run by Evinox and the block's heat supplier, so account and credit questions go to them.

HIU servicing is priced per unit. The price depends on the number of units, access to the flats and whether repairs are needed. Booking all the flats in a block together lowers the cost per flat, and in London the site visit to quote is free.

Emergency line. Same-day response across London.

Something broken right now? Speak to an engineer.

A clear price before any work starts, and a written report after. For planned servicing, compliance certificates and contracts, WhatsApp us and we will call you back.

REFCOM certified REF1024168Gas Safe registered engineersSafeContractor approvedNICEIC certified electricians

Emergency HVAC and heating repair in London