Danfoss · EvoFlat · Termix · London
Danfoss HIU Service and Repair in London
Servicing, repairs and replacement for Danfoss heat interface units in London flats, build-to-rent blocks and heat networks, by manufacturer-approved, SAV certified engineers, with a 24/7 HIU call-out line.
- Danfoss approved
- Free site visit in London
- 24/7 HIU call-out

Who services Danfoss HIUs in London?
Mainteniq services, repairs and replaces Danfoss heat interface units across London and the Home Counties. Our engineers are manufacturer approved for Danfoss and SAV units, Evinox trained and certified, and hold the SAV Advanced HIU Service Engineer certificate. Every visit ends with a report with photos and the readings taken, and our emergency line runs 24/7 for no heating or no hot water.
Danfoss is one of the most common heat interface unit makers in London blocks on communal heating, so many managing agents and residents have one in a cupboard without knowing it. If the label says Danfoss, EvoFlat or Termix, this is the right page. For every other make, see our HIU service and repair page.
How a Danfoss HIU Works
A heat interface unit is the small box that connects one flat to the building's shared heating. It takes heat from the network and turns it into the flat's own hot water and heating, so the flat needs no boiler.
- STEP 1
Heat from the network
Hot water arrives from the block's plant room or a district heat network, through the flow pipe into the flat.
- STEP 2
Heat meter and valves
The heat meter records what the flat uses. The control valves, on many Danfoss units a TPC-M controller, let the right amount of heat in.
- STEP 3
Plate heat exchanger
Inside the HIU, heat passes through a plate heat exchanger to the flat's own water. The network water and tap water never mix.
- STEP 4
Hot water and heating
Instant hot water at the taps and shower, and heat for radiators or underfloor heating, set by the flat's thermostat.
- STEP 5
Cooler water returns
The cooler water goes back to the network through the return pipe. A low return temperature is the sign of a healthy unit.
Because tap water and network water never mix, most hot water faults sit at the strainers, the plate heat exchanger or the controller: all inside the HIU, and all serviceable.
Know your unit
Which Danfoss HIU Do You Have?
The model name is on the label inside the cupboard or on the casing. These are the Danfoss names we see most in London flats.
EvoFlat
Danfoss's modular flat station range, including units for heating with instant hot water. Common in London new-build and BTR blocks.
Termix
Danfoss's Termix flat stations and hot water units, found in many communal heating schemes.
Older FlatStation units
Earlier Danfoss heat interface units still running in blocks built over the last fifteen years or so.

Common Danfoss HIU Problems and What Causes Them
Danfoss's own troubleshooting tables point to the same handful of causes we find on site. Most are fixed without replacing the unit.
No hot water
Danfoss's own fault tables start with a blocked strainer on the cold supply or the primary, then low supply flow or pressure. Usually fixed by cleaning and testing.
Lukewarm or slow hot water
A scaled plate heat exchanger, a worn controller or a mixing valve out of setting. Descaling or a part change brings it back.
TPC-M controller faults
The controller that balances hot water against the supply can stick or wear. Danfoss publishes a service kit to exchange it.
Heating will not come on
A failed actuator, a sticking zone valve, a thermostat or wiring fault, or a heating circuit pump that has stopped.
Noise and pressure drops
Air in the system, a failing pump or a high differential pressure from the network. Checked at the HIU and the riser.
Leaks and drips
Perished seals, washers and fittings inside the casing. Caught early, a small leak does not become a ceiling below.
Is only one room cold on underfloor heating fed by the HIU? The fault may be at the manifold instead: see underfloor heating repair. Is the whole block without heat? Call our 24/7 emergency line, and see heat network maintenance.
What we do
Danfoss HIU Services
From a single flat with no hot water to every unit in a block, by engineers who work on Danfoss units every week.

Danfoss HIU service
Strainers cleaned, plate heat exchanger checked, controller and valves tested, flow and return temperatures recorded, report with photos.
HIU servicingDanfoss HIU repair
No hot water, no heating, noise, leaks and controller faults, traced to the part and repaired. We always aim to fix it on the first visit.
Descaling and heat exchangers
Scaled plate heat exchangers descaled or replaced so hot water comes back to temperature.
Controllers and valves
TPC-M controllers, thermostatic and zone valves, actuators and thermostats exchanged with the correct Danfoss parts.
HIU installation and replacement
New and replacement heat interface units installed, commissioned and handed over with readings, where a unit is beyond economic repair.
Whole-block programmes
Every Danfoss unit in a block on one programme, with access arranged, a report per flat and a block summary.
Block contracts2 years
the longest gap Danfoss allows between inspections
How Often Should a Danfoss HIU Be Serviced?
Danfoss's installation guides say its flat stations should be inspected at least every two years. In London blocks we recommend an annual service: hard water scales plate heat exchangers and blocks strainers faster, and a yearly visit catches a slow hot water complaint before it becomes no hot water. Spare parts are ordered against the unit's serial number, which we record on every report.
Read more: how often should an HIU be serviced?
24/7 HIU Call-Out for No Heating or No Hot Water
Our emergency line is answered day and night, weekends included. In London we aim to attend the same day. We always aim to fix the fault on the first visit; if a part has to be ordered, the flat is made safe and you get a fixed price first.
How a Danfoss HIU Job Works
- 1
Free site visit
We look at the HIU, the riser and the controls. Free in London; in the Home Counties, free for larger jobs, otherwise we quote the visit first.
- 2
Report with photos
Which Danfoss unit you have, what is working, what is worn and what needs doing, sent by email.
- 3
Clear price
A fixed price for the repair or service before any work, priced per unit for blocks.
- 4
Planned visits
Annual servicing on an agreed schedule, with a new report every visit.
A photographed PDF report after every Danfoss HIU service
No handwritten job sheets and no chasing. Our engineers complete each job electronically on site in Maintivo, our job management system, so the report is built as the work happens: photos, readings, work done and recommendations.
You receive it as a digital PDF by email the same day, with certificates attached where they apply, ready to forward to a landlord, a freeholder, the directors or an insurer.
- Before and after photosEvery unit and fault photographed on site
- Readings and checksTemperatures, pressures and test results recorded
- Work done and next stepsWhat was fixed, what needs quoting, when we return
- Sent the same dayDigital PDF report by email, ready to forward
Example layout. Completed on site in Maintivo.
Qualifications Behind the Work
What customers say on Google
“I've had the pleasure of working with Petru and his team on a number of maintenance jobs, and they've always been fantastic. They're professional, reliable, and complete every job to a really high standard. Petru is incredibly knowledgeable and it's clear he takes pride in his work.”
Deborah L.
Google review
“Excellent service. Price assessment: reasonable price.”
Attila B.
Google review
“The team is knowledgeable, efficient, and attentive to detail. A great choice for anyone looking for reliable maintenance services. Highly recommended!”
Ben
Google review
Book a Free Danfoss HIU Site Visit
In London an engineer comes to see your Danfoss HIU for free; in the Home Counties it is free for larger jobs, and for smaller ones we quote the visit first. You get a report with photos and a fixed price before any work.