Altecnic · SATK · SmartSat · London
Altecnic HIU Service and Repair in London
Servicing, repairs and replacement for Altecnic SATK heat interface units in London flats, build-to-rent blocks and heat networks, by SAV certified, HIU trained engineers, with a 24/7 HIU call-out line.
- Every SATK model
- Free site visit in London
- 24/7 HIU call-out

Who services Altecnic HIUs in London?
Mainteniq services and repairs Altecnic heat interface units across London and the Home Counties, including the SATK20, SATK22, SATK30, SATK32, SATK40 and SATK102. Our engineers hold the SAV Advanced HIU Service Engineer certificate and Herts Energy Academy HIU training, and we work to the checks in Altecnic's own installation, operation and maintenance manuals. Every visit ends with a report with photos and readings, and our emergency line runs 24/7 for no heating or no hot water.
Altecnic is a UK company based in Stafford and part of the Caleffi Group. Altecnic describes Caleffi as its Italy-based manufacturing partner and parent company, and the SATK manuals carry the Caleffi name. That is why the label or manual on your unit may say Altecnic, Caleffi or both. If yours says Caleffi, see our Caleffi HIU page. For every other make, see HIU service and repair.
How an Altecnic HIU Works
Altecnic sells its electronic heat interface units under the name SmartSat. Each one connects a single flat to the building's shared heating and turns heat from the network into the flat's hot water and heating, so the flat needs no boiler.
- STEP 1
Heat from the network
Hot water from the block's plant room or a district heat network enters the HIU through a mesh strainer and a differential pressure regulating valve.
- STEP 2
Electronic controller
The SATK controller reads its temperature probes and drives two modulating valves, one for hot water and one for heating, so only the heat needed is let in.
- STEP 3
Plate heat exchangers
On indirect units such as the SATK32 and SATK30, one plate heat exchanger makes instant hot water and a second heats the flat's own sealed heating circuit.
- STEP 4
Hot water and heating
A flow meter senses a hot tap opening and gives hot water priority. A pump, expansion vessel and pressure switch run the heating side for radiators or underfloor heating.
- STEP 5
Cooler water returns
Cooled water goes back to the network. A return temperature probe lets the unit limit how hot the return gets, which keeps the whole heat network efficient.
Altecnic points out that every component sits inside the HIU casing, which is what makes these units straightforward to service: strainers, exchangers, valves and probes can all be reached in the cupboard.
Know your unit
Which Altecnic HIU Do You Have?
The model code starts with SATK and is on the label inside the cover. These are the Altecnic ranges in Altecnic's current UK line-up.
SATK32
Indirect unit with network protection and an integral room controller. Up to 15 kW heating, primary return temperature and flow rate limitation, Modbus output.
SATK30
Indirect, twin-plate unit with electronic control for instant hot water and space heating, for radiator or underfloor heating temperatures.
SATK20 and SATK22
Direct units with electronic control, made in low, medium and high temperature versions. The SATK22 controls heating and hot water independently.
SATK40
Indirect, electronically controlled unit for heating that connects to an indirect hot water cylinder.
SATK102
Wall-mounted hot water unit with electronic control and a settable hot water temperature. Units can be cascaded for higher outputs.
Source: Altecnic's heat interface units range pages. Direct units send network water through the flat's heating; indirect units keep it separate with a second heat exchanger.
Send a photo of your HIU label
Common Altecnic HIU Problems and What Causes Them
These come from the troubleshooting tables and error codes in Altecnic's SATK32 manual, and match what we find on site. Most are fixed without replacing the unit.
No hot water at all
Altecnic's SATK32 fault table lists closed primary shut-off valves, a modulating valve actuator that is loose or faulty, a valve stuck closed, air in the unit, a controller fault, or a cold network.
Hot water never gets hot enough
A clogged primary strainer, a partly blocked heat exchanger, the return temperature limit cutting in, or a primary flow limit set too low. Cleaning and correct settings usually fix it.
Weak or no flow at the tap
The manual points first to a clogged HIU strainer, then to part-closed cold water valves, low cold water pressure in the building, or a fully blocked exchanger.
Rooms will not warm up
A clogged strainer, a heating valve actuator or obturator that has failed, a pump that has stopped, air in the system, or a room thermostat programmed wrongly.
Error code 4: heating pressure
The pressure switch has tripped because the heating circuit pressure is too low. Altecnic notes a low expansion vessel pre-charge can cause it. Hot water keeps working.
Error codes 69 and 80
Code 69 is the safety thermostat cutting out on low temperature heating and needs a reset. Code 80 means the unit is disabled by its wiring or by a pre-payment system with no credit.

Is only one room cold on underfloor heating fed by the HIU? The fault may be at the manifold instead: see underfloor heating repair. Is the whole block without heat? The fault table's last line, a cold network, points to the plant room: call our 24/7 emergency line and see heat network maintenance.
What we do
Altecnic HIU Services
From one flat with an error code on the display to every SATK unit in a block, by engineers trained in heat interface unit fault finding.

Altecnic HIU service
The checks in Altecnic's manual: three strainers cleaned, expansion vessel pre-charge and heating pressure set, relief valve and valves checked, error codes read, report with photos.
HIU servicingAltecnic HIU repair
No hot water, cold rooms, error codes, leaks and noise, traced to the part and repaired. We always aim to fix it on the first visit.
Descaling and heat exchangers
Partly blocked plate heat exchangers cleaned or replaced, with new O-rings, so hot water comes back to temperature.
Controls, probes and valves
Modulating valve actuators and obturators, temperature probes, flow meters and room controllers exchanged and the settings checked.
HIU installation and replacement
New and replacement heat interface units installed, commissioned and handed over with readings, where a unit is beyond economic repair.
Whole-block programmes
Every Altecnic unit in a block on one programme, with access arranged, a report per flat and a block summary.
Block contracts12 months
the longest gap Altecnic's manual allows between checks
How Often Should an Altecnic HIU Be Serviced?
Altecnic's SATK32 manual says its maintenance checks must be carried out at least once every 12 months, in line with the standard EN 806-5. The list includes cleaning the strainers on the primary flow, the secondary return and before the hot water flow meter, checking the expansion vessel pre-charge and heating pressure, checking the safety relief valve and looking for valves that let heat through when nothing is on. The manual also recommends a hot water set point of 50°C or lower unless there is a reason for higher. For spare parts the manual sends enquiries to Caleffi; we record the model code on every report so the right part can be identified.
Read more: how often should an HIU be serviced?
24/7 HIU Call-Out for No Heating or No Hot Water
Our emergency line is answered day and night, weekends included. In London we aim to attend the same day. Tell us the error code on the display when you call. We always aim to fix the fault on the first visit; if a part has to be ordered, the flat is made safe and you get a fixed price first.
How an Altecnic HIU Job Works
- 1
Free site visit
We look at the HIU, its error codes, the riser and the controls. Free in London; in the Home Counties, free for larger jobs, otherwise we quote the visit first.
- 2
Report with photos
Which SATK model you have, what is working, what is worn and what needs doing, sent by email.
- 3
Clear price
A fixed price for the repair or service before any work, priced per unit for blocks.
- 4
Planned visits
Annual servicing on an agreed schedule, with a new report every visit.
A photographed PDF report after every Altecnic HIU service
No handwritten job sheets and no chasing. Our engineers complete each job electronically on site in Maintivo, our job management system, so the report is built as the work happens: photos, readings, work done and recommendations.
You receive it as a digital PDF by email the same day, with certificates attached where they apply, ready to forward to a landlord, a freeholder, the directors or an insurer.
- Before and after photosEvery unit and fault photographed on site
- Readings and checksTemperatures, pressures and test results recorded
- Work done and next stepsWhat was fixed, what needs quoting, when we return
- Sent the same dayDigital PDF report by email, ready to forward
Example layout. Completed on site in Maintivo.
Qualifications Behind the Work
What customers say on Google
“I've had the pleasure of working with Petru and his team on a number of maintenance jobs, and they've always been fantastic. They're professional, reliable, and complete every job to a really high standard. Petru is incredibly knowledgeable and it's clear he takes pride in his work.”
Deborah L.
Google review
“Excellent service. Price assessment: reasonable price.”
Attila B.
Google review
“The team is knowledgeable, efficient, and attentive to detail. A great choice for anyone looking for reliable maintenance services. Highly recommended!”
Ben
Google review
Book a Free Altecnic HIU Site Visit
In London an engineer comes to see your Altecnic HIU for free; in the Home Counties it is free for larger jobs, and for smaller ones we quote the visit first. You get a report with photos and a fixed price before any work.