Caleffi · SATK22 · SATK30 · SATK32 · London

Caleffi HIU Service and Repair in London

Servicing, repairs and replacement for Caleffi SATK heat interface units, direct and indirect, in London flats, build-to-rent blocks and heat networks, by SAV certified, HIU trained engineers, with a 24/7 HIU call-out line.

Call +44 783 456 2366
  • Direct and indirect units
  • Free site visit in London
  • 24/7 HIU call-out
Wall-mounted heat interface unit with flow and return gauges in a London flat cupboard, ready for a Mainteniq London service

Who services Caleffi HIUs in London?

Mainteniq services and repairs Caleffi heat interface units across London and the Home Counties, including the SATK22, SATK30 and SATK32 ranges and the mechanical SATK16315. Our engineers hold the SAV Advanced HIU Service Engineer certificate and Herts Energy Academy HIU training, and we follow the maintenance steps in Caleffi's own installation, commissioning and maintenance manuals. Every visit ends with a report with photos and readings, and our emergency line runs 24/7 for no heating or no hot water.

Caleffi is an Italian manufacturer. In the UK its heat interface units are supplied by Altecnic, a Stafford company in the Caleffi Group, so the same unit can carry either name. If your label says Altecnic, see our Altecnic HIU page. For every other make, see HIU service and repair.

How a Caleffi HIU Works

Caleffi describes its SATK units as controlling the heating and hot water of one flat independently, on a central boiler system or a district heat network. Here is the path the heat takes.

  1. STEP 1

    Network water arrives

    Hot water from the plant room or district heat network comes in through a mesh strainer and a differential pressure control valve that steadies the supply.

  2. STEP 2

    A tap opens

    A flow meter, a small turbine and sensor, detects the hot tap. Hot water takes priority and the controller opens the hot water modulating valve.

  3. STEP 3

    Hot water exchanger

    Network heat passes through a brazed plate heat exchanger to the flat's mains water, so hot water is made instantly with no cylinder.

  4. STEP 4

    Heating: direct or indirect

    On a direct SATK22 the network water flows round the flat's radiators or underfloor heating. On an indirect SATK30 or SATK32 a second exchanger keeps the two separate.

  5. STEP 5

    Cooled water returns

    Cooled water goes back to the network past a return temperature probe. Low temperature SATK22 units also carry a normally closed thermal safety solenoid valve.

Caleffi's controllers also run the pump for a few seconds and move the valves once every 24 hours when they are idle, so they do not seize. Scale and debris can still build up inside, which a service picks up.

Know your unit

Which Caleffi HIU Do You Have?

The SATK code is on the label inside the cover. These are the Caleffi ranges in Caleffi's own manuals and data sheets.

SATK22 (direct, wall-mounted)

Low, medium and high temperature versions. The code shows which: SATK2210x is low, SATK2220x medium, SATK2230x and SATK2240x high, and the SATK2240x adds a primary pump.

SATK30 (indirect, double wall-mounted)

Separate heating water with instant hot water. Caleffi lists the SATK30103HE at 40 kW and the SATK30105HE at 65 kW of hot water.

SATK32 (indirect, wall-mounted)

SATK32103, SATK32105 and SATK32107, the last for low temperature heat networks. Electronic control with Modbus.

SATK16315 (mechanical)

Hot water and high temperature heating with mechanical control, a 30 kPa differential pressure valve, a zone valve and a thermostatic mixing valve made from anti-scale materials.

Send a photo of your HIU label

Direct or indirect?

Direct (SATK22)

Network water runs straight through the flat's radiators or underfloor heating, so the flat's heating shares the network's water.

Indirect (SATK30, SATK32)

A second plate heat exchanger gives the flat its own sealed heating circuit, with its own pump, expansion vessel and pressure gauge.

Inside an indirect heat interface unit in a London flat, with insulated heat exchangers, expansion vessel and heat meter
Inside an indirect unit: insulated exchangers, the red expansion vessel and the heat meter below.

Common Caleffi HIU Problems and What Causes Them

Caleffi's SATK22 and SATK30 manuals carry a fault table for every symptom. These are the causes they list, and the ones we find most on site.

No hot water

Caleffi's fault tables list closed primary valves, a disconnected or faulty valve actuator, a valve stuck closed, air, a cold network, and a disconnected or faulty hot water flow meter.

Hot water lukewarm

A clogged primary strainer, a partly blocked heat exchanger, a faulty actuator, too many taps open at once, or low temperature or flow from the network.

Hot water too hot

A set point too high, a valve stuck part open, a faulty actuator or controller, or too much pressure on the primary side from the network.

Low or no flow at the tap

First a clogged or completely blocked HIU strainer, then a blocked exchanger, part-closed cold water valves or a weak cold supply in the building.

Rooms not reaching temperature

A clogged strainer, a heating valve actuator or obturator fault, a pump that has stopped or come unplugged, air in the system, or thermostat programming.

Error codes 4, 69 and 76

Code 4 is low heating pressure, often a low expansion vessel pre-charge. Code 69 is the safety thermostat cutting out. Code 76 is a fault on the thermal safety valve of low temperature SATK22 units.

On SATK30 units Caleffi also lists codes 79 and 80 for an incorrect dip-switch setting. A direct SATK22 on underfloor heating with one cold room may have a manifold fault instead: see underfloor heating repair. If the whole block has lost heat, call our 24/7 emergency line and see heat network maintenance.

What we do

Caleffi HIU Services

From a single flat with lukewarm hot water to every SATK unit in a block, by engineers trained in heat interface unit fault finding.

Clogged heat interface unit strainer beside a clean one, removed by a Mainteniq London engineer during an HIU service
A clogged strainer against a clean one. Caleffi's tables name it for low flow, lukewarm hot water and cold rooms.

Caleffi HIU service

Strainers and the flow meter turbine cleaned, exchanger checked, expansion vessel pre-charge and pressure set, valves tested, readings and photos in the report.

HIU servicing

Caleffi HIU repair

No hot water, lukewarm or scalding hot water, cold rooms, error codes and leaks, traced to the part and repaired. We always aim to fix it on the first visit.

Descaling and heat exchangers

Partly blocked plate heat exchangers cleaned or exchanged with new O-rings, fitted the right way round as Caleffi's manual requires.

Controls, flow meters and valves

Actuators, valve obturators, temperature probes and hot water flow meters replaced, and dip-switch and set point settings checked.

HIU installation and replacement

New and replacement heat interface units installed, commissioned and handed over with readings, where a unit is beyond economic repair.

Whole-block programmes

Every Caleffi unit in a block on one programme, with access arranged, a report per flat and a block summary.

Block contracts

6 months

how often Caleffi says to check the expansion vessel

How Often Should a Caleffi HIU Be Serviced?

Caleffi's SATK30 manual says to check the expansion vessel pre-charge at least once every six months, because a low pre-charge trips the heating pressure switch. Its SATK32 instructions set the full list of checks at least once every 12 months, in line with EN 806-5: strainers cleaned, valves checked for leaking through, relief valve and pressures checked, and hot water flow tested at temperature. We service Caleffi units every year and check the vessel at each visit. Caleffi's manuals send spare parts enquiries to Caleffi itself, so we record the full SATK code on every report.

Read more: HIU inspection vs HIU service

24/7 HIU Call-Out for No Heating or No Hot Water

Our emergency line is answered day and night, weekends included. In London we aim to attend the same day. We always aim to fix the fault on the first visit; if a part has to be ordered, the flat is made safe and you get a fixed price first.

Call 24/7

How a Caleffi HIU Job Works

  1. 1

    Free site visit

    We look at the HIU, the fault LED or display, the riser and the controls. Free in London; in the Home Counties, free for larger jobs, otherwise we quote the visit first.

  2. 2

    Report with photos

    Which Caleffi model and temperature class you have, what is working, what is worn and what needs doing.

  3. 3

    Clear price

    A fixed price for the repair or service before any work, priced per unit for blocks.

  4. 4

    Planned visits

    Annual servicing on an agreed schedule, with the expansion vessel checked as Caleffi advises.

Digital reports, not paperwork

A photographed PDF report after every Caleffi HIU service

No handwritten job sheets and no chasing. Our engineers complete each job electronically on site in Maintivo, our job management system, so the report is built as the work happens: photos, readings, work done and recommendations.

You receive it as a digital PDF by email the same day, with certificates attached where they apply, ready to forward to a landlord, a freeholder, the directors or an insurer.

  • Before and after photosEvery unit and fault photographed on site
  • Readings and checksTemperatures, pressures and test results recorded
  • Work done and next stepsWhat was fixed, what needs quoting, when we return
  • Sent the same dayDigital PDF report by email, ready to forward

Example layout. Completed on site in Maintivo.

Qualifications Behind the Work

SAV Advanced HIU Service EngineerCertificate PERS-30839
HIU trainingHerts Energy Academy heat interface unit training
Manufacturer approvedFor SAV and Danfoss units; Evinox trained and certified. Caleffi units serviced to Caleffi's own manuals
REFCOM F-Gas certifiedREF1024168
NICEIC Domestic VentilationDV-02 certified
NICEIC certified electriciansGas work by Gas Safe registered engineers

What customers say on Google

5.0Google rating
“I've had the pleasure of working with Petru and his team on a number of maintenance jobs, and they've always been fantastic. They're professional, reliable, and complete every job to a really high standard. Petru is incredibly knowledgeable and it's clear he takes pride in his work.”

Deborah L.

Google review

“Excellent service. Price assessment: reasonable price.”

Attila B.

Google review

“The team is knowledgeable, efficient, and attentive to detail. A great choice for anyone looking for reliable maintenance services. Highly recommended!”

Ben

Google review

Read all reviews on Google

Book a Free Caleffi HIU Site Visit

In London an engineer comes to see your Caleffi HIU for free; in the Home Counties it is free for larger jobs, and for smaller ones we quote the visit first. You get a report with photos and a fixed price before any work.

WhatsApp us Call

Caleffi HIU: Common Questions

Yes. Mainteniq services and repairs Caleffi heat interface units across London and the Home Counties, including the SATK22 direct, SATK30 and SATK32 indirect and the mechanical SATK16315. Our engineers hold the SAV Advanced HIU Service Engineer certificate and Herts Energy Academy HIU training, and we follow the maintenance steps in Caleffi's own manuals. Every visit ends with a report with photos, and our 24/7 line covers no heating or no hot water, with a same-day aim across London.

Often, yes. Caleffi is an Italian manufacturer and Altecnic, based in Stafford, is part of the Caleffi Group and supplies Caleffi's SATK units in the UK. The same unit can carry either name on its label or manual. We service both.

Caleffi's fault tables list a clogged primary strainer, a partly blocked heat exchanger, a faulty valve actuator, too much hot water being drawn at once, and low temperature or flow from the heat network. A clogged strainer is the easiest to fix: once it is cleaned the hot water often comes straight back to temperature.

On a direct unit such as the SATK22, the heat network's water runs through the flat's radiators or underfloor heating. On an indirect unit such as the SATK30 or SATK32, a second plate heat exchanger gives the flat its own sealed heating circuit with its own pump, expansion vessel and pressure. Both make instant hot water through a plate heat exchanger.

Caleffi's SATK30 manual says to check the expansion vessel pre-charge at least once every six months, and its SATK32 instructions set the full maintenance checks at least once every 12 months, in line with EN 806-5. We service Caleffi units every year and check the expansion vessel at every visit.

Code 4 means the heating circuit pressure switch has tripped because the pressure is too low, and Caleffi notes a low expansion vessel pre-charge can cause it. Code 69 is the safety thermostat cutting out on low temperature heating and needs the reset button. Code 76 is a fault on the thermal safety valve fitted to low temperature SATK22 units.

HIU servicing is priced per unit. The price depends on the number of units, access to the flats and whether repairs are needed. Booking all the flats in a block together lowers the cost per flat, and in London the site visit to quote is free.

No. Mainteniq is an independent heating and building services contractor and is not approved by or partnered with Caleffi. We service and repair Caleffi heat interface units following Caleffi's published manuals. Our engineers are manufacturer approved for SAV and Danfoss units, Evinox trained and certified, and hold the SAV Advanced HIU Service Engineer certificate.

Emergency line. Same-day response across London.

Something broken right now? Speak to an engineer.

A clear price before any work starts, and a written report after. For planned servicing, compliance certificates and contracts, WhatsApp us and we will call you back.

REFCOM certified REF1024168Gas Safe registered engineersSafeContractor approvedNICEIC certified electricians

Emergency HVAC and heating repair in London