Fan coil units · Offices, hotels and blocks · London

Fan Coil Unit Refurbishment and Replacement in London

Tired, noisy or failing fan coils do not always need replacing. We survey every unit, tell you which to service, refurbish or replace, give a fixed price for each, and carry out the work floor by floor while the building stays in use.

+44 783 456 2366
  • Unit-by-unit survey with photos
  • Fixed price per unit
  • Worked around your occupants
Mainteniq London photo of a row of ceiling fan coil units exposed on a London office floor during a refurbishment programme, each tagged for survey, with desks under dust sheets below
  • 1,000+properties served across London
  • 4-hour responsewe come back to you within 4 hours
  • Guaranteedworkmanship on every job
  • £5M insuredpublic liability, SafeContractor approved

What is fan coil unit refurbishment?

Fan coil refurbishment means keeping the parts of the unit that are still good, usually the casing, coil and pipework, and replacing the parts that wear out: fan motors, valves, actuators, controls, drip trays and filters. Each unit is then deep cleaned, recommissioned and tested.

Because the casing and coil stay in the ceiling, refurbishment avoids taking ceilings and pipework apart, so it is often quicker and less disruptive than replacement. Mainteniq refurbishes fan coil units in London offices, hotels and residential blocks. For routine servicing and repairs, see FCU maintenance.

Signs your fan coils need more than a service

  • Noisy fans even after cleaning
  • Rooms that never reach temperature
  • Repeated leaks from rusted drip trays
  • Valves or actuators failing one after another
  • Controllers that no longer talk to the BMS
  • Parts the old maker no longer supplies
Send us photos

How to decide

Service, Refurbish or Replace?

The survey puts every unit into one of three groups. Most buildings end up with a mix, which is why we price unit by unit.

Service

Dirty, not worn

Weak airflow, musty smells, drips or noise from dust. A full service of the filter, coil, fan, drip tray and drain usually brings the unit back.

FCU servicing
Refurbish

Sound casing and coil, worn parts

Tired fan motors, sticking valves, failed actuators or old controls, but a casing and coil that are still good. Replace the parts, keep the unit.

Replace

Coil or casing past saving

A leaking or corroded coil, a rusted casing or drip tray, parts no longer made, or a unit that still cannot heat or cool the room after a full service.

What the survey looks at on each unit

What a fan coil survey checks
PartWhat we checkPoints towards
CoilLeaks, corrosion, blocked or flattened finsClean if sound; replace the coil or unit if leaking
Casing and drip trayRust, holes, sagging, loose panelsRefurbish if sound; new tray or unit if rusted through
Fan and motorNoise, vibration, current draw, AC or EC motorNew EC fan deck if worn or noisy
Valves and actuatorsOpen and shut fully, no water passing when closedNew valves and actuators if sticking or passing
ControlsController age, sensor, link to the BMSNew controllers if obsolete or unsupported
Parts supplyMake, model, whether spares are still madeReplacement if parts are no longer available

What a Fan Coil Refurbishment Includes

Only what the survey shows each unit needs. A unit with a good fan and valves may only need a deep clean, new filters and new controls.

Deep clean

Coil fins cleaned and straightened, casing vacuumed, drip tray cleaned and disinfected, condensate drain flushed and tested.

New fan deck or motor

Worn or noisy fans replaced, usually with an EC fan deck that uses less electricity and gives smooth speed control.

Valves and actuators

Sticking or passing control valves and failed actuators replaced, with new isolating valves and flexible hoses where they are perished.

Controls

New unit controllers and room sensors, set up to work with the existing building management system or a new one.

Drainage

Rusted drip trays and failed condensate pumps replaced, and pipe falls corrected so water drains away.

Filters and seals

New filters and frames, access panels re-sealed so air goes through the filter, not round it.

Pipe insulation

Damaged insulation on chilled water pipes replaced so condensation does not drip outside the tray.

Recommissioning

Each unit run in heating and cooling, airflow and water temperatures checked, and settings recorded.

Mainteniq London photo of an old dust-clogged fan coil fan deck beside a new EC fan deck of the same size on a dust sheet during a fan coil refurbishment, with a used filter and a drill
An old fan deck clogged with dust beside its new EC replacement, same size and fixings, ready to go back into the ceiling.

Why EC fan decks are the usual upgrade

Many older fan coils run on AC motors with a few fixed speeds. An EC (electronically commutated) fan deck is made to fit the same casing, uses less electricity, runs more quietly and lets the controller set the fan speed smoothly.

Where the building has a BMS, the new fan speed and valve signals are set up so the controls and the mechanical parts work together, checked in the same visit.

How a Refurbishment Programme Works

The same four steps on one flat or a whole office building, so you know the cost of every unit before any work starts.

  1. 1

    Survey every unit

    An engineer opens and photographs each fan coil, tests the fan, valves, drain and controls, and notes the make and model.

  2. 2

    Report and fixed prices

    You get a unit-by-unit report: service, refurbish or replace, the reason and photos, with a fixed price for each unit, in priority order.

  3. 3

    Programme around you

    Work is planned floor by floor, room by room or flat by flat, out of hours where needed, so the building stays in use.

  4. 4

    Refurbish and hand over

    Units are refurbished or replaced, recommissioned and tested, with a photographed report and an updated asset list at the end.

Fan Coil Refurbishment in Occupied Buildings

Most fan coils sit above people who are working, sleeping or living below them. The programme is built around them.

Offices

Floors between tenants or ahead of a lease renewal, and occupied floors in phases, out of hours if needed.

Hotels

Room by room between guests, so no more rooms are out of service than agreed with the hotel.

Residential blocks and BTR

Flat by flat with access arranged through the managing agent or concierge, and a report for each flat.

Prime apartments

Single flats with concealed units in the ceiling, worked in with dust sheets and care for finishes.

What Affects the Cost

Every unit is priced after the survey, so the figure covers what is really in your ceiling. These are the things that move it.

What affects the cost of fan coil refurbishment
FactorWhy it matters
Number of unitsLarger programmes bring the price per unit down
AccessCeiling type and height, tight hatches, and whether furniture or finishes need protecting
Parts replacedA deep clean and new filters costs far less than new fan decks, valves and controls
ControlsWhether the new controllers must talk to an existing BMS
Working hoursOut-of-hours or weekend work to avoid disturbing occupants
Replacement unitsSize, type and lead time of like-for-like units where coils or casings are past saving

Refurbishing the existing unit is often the cheaper route than replacing it, and the survey shows you both where it is a close call.

When a Fan Coil Unit Is Replaced

Where a unit is past saving, we replace it like for like, matched to the space in the ceiling, the pipe connections and the controls, so the rest of the system is not disturbed.

  • Matched to what is thereSize, capacity, pipe connections, 2-pipe or 4-pipe, and controls checked at the survey.
  • Isolated, swapped and reconnectedWater isolated at the unit, new unit hung and connected, drain and controls reconnected.
  • RecommissionedRun in heating and cooling, airflow and water temperatures checked, settings recorded.
  • Old units taken awayRemoved units are taken off site and disposed of responsibly.
Digital reports, not paperwork

A photographed PDF report after every fan coil survey

No handwritten job sheets and no chasing. Our engineers complete each job electronically on site in Maintivo, our job management system, so the report is built as the work happens: photos, readings, work done and recommendations.

You receive it as a digital PDF by email the same day, with certificates attached where they apply, ready to forward to a landlord, a freeholder, the directors or an insurer.

  • Before and after photosEvery unit and fault photographed on site
  • Readings and checksTemperatures, pressures and test results recorded
  • Work done and next stepsWhat was fixed, what needs quoting, when we return
  • Sent the same dayDigital PDF report by email, ready to forward

Example layout. Completed on site in Maintivo.

Who Does the Work

REFCOM F-Gas certifiedREF1024168
SafeContractor approvedHealth and safety accredited
BMS trainedTrend, Siemens, Honeywell, Tridium
Workmanship guaranteeOn the work we carry out

More than 1,000 properties served across London. Every unit gets a photographed report.

What customers say on Google

5.0Google rating
“I've had the pleasure of working with Petru and his team on a number of maintenance jobs, and they've always been fantastic. They're professional, reliable, and complete every job to a really high standard. Petru is incredibly knowledgeable and it's clear he takes pride in his work.”

Deborah L.

Google review

“Excellent service. Price assessment: reasonable price.”

Attila B.

Google review

“The team is knowledgeable, efficient, and attentive to detail. A great choice for anyone looking for reliable maintenance services. Highly recommended!”

Ben

Google review

Read all reviews on Google

Find Out What Your Fan Coils Need

Book a survey. You get a photographed report on every unit, a clear service, refurbish or replace recommendation, and a fixed price for each.

+44 783 456 2366 WhatsApp us

Fan Coil Refurbishment: Common Questions

Fan coil refurbishment keeps the parts of the unit that are still good, usually the casing, coil and pipework, and replaces the parts that wear out: fan motors or fan decks, valves, actuators, controls, drip trays and filters. Each unit is then deep cleaned, recommissioned and tested. Mainteniq refurbishes fan coil units in London offices, hotels and residential blocks.

Refurbish when the casing and coil are sound but the fan, valves, actuators or controls are worn. Replace when the coil leaks or is corroded, the casing or drip tray has rusted through, parts are no longer made, or the unit still cannot heat or cool the room after a full service. Our survey puts each unit into service, refurbish or replace, with photos and the reason.

Yes. EC fan decks are made to fit existing fan coil casings in place of older AC motors. They use less electricity, run more quietly and let the controller set the fan speed smoothly. We check the unit, the controls and any BMS connection at the survey so the new fan deck works with what is already there.

Yes. Work is planned floor by floor in offices, room by room between guests in hotels, and flat by flat in residential blocks, with out-of-hours working where it is needed. Dust sheets go down under every unit, and each area is handed back tested before the next one starts.

Each unit is priced after a survey, because the cost depends on what each one needs, how many units there are, access to the ceiling void, the controls and whether work has to be out of hours. You get a fixed price for every unit before anything starts, and larger programmes bring the price per unit down.

It depends on the size and type of unit, whether it is ceiling, floor or wall mounted, access to the ceiling void, the pipework and valves, and the controls it has to work with. We quote each replacement after the survey, and where refurbishing the existing unit would do the job for less, the report says so.

That is checked at the survey. Our engineers are BMS trained on Trend, Siemens, Honeywell and Tridium systems, so new controllers are chosen and set up to work with the building management system already in place, and the fan coils and controls are tested together before handover.

Yes. Removed units, fan decks, valves and filters are taken off site and disposed of responsibly, and the area under each unit is left clean.

Emergency line. Same-day response across London.

Something broken right now? Speak to an engineer.

A clear price before any work starts, and a written report after. For planned servicing, compliance certificates and contracts, WhatsApp us and we will call you back.

REFCOM certified REF1024168Gas Safe registered engineersSafeContractor approvedNICEIC certified electricians

Emergency HVAC and heating repair in London